SPT (Service Parallel Thermoplastic) cords

SPT-1 SPT-2 SPT-3 SPT-1W SPT-2W SPT-2-R

SPT (Service Parallel Thermoplastic) cords. They are primarily used for low-power applications within dry environments, such as:

  • Lamps and lighting fixtures
  • Christmas lights
  • Small appliances (fans, radios)
  • Extension cords (limited to specific lengths)

Here’s a breakdown of their key differences:

Code Description
SPT-1 Two parallel conductors with a thin thermoplastic insulation layer.
SPT-2 Two parallel conductors with a medium thickness thermoplastic insulation layer.
SPT-3 Two parallel conductors with a thick thermoplastic insulation layer.

 

Thickness Differences:

  • SPT-1: Thinnest insulation – suitable for very low-power applications like Christmas lights.
  • SPT-2: Medium thickness insulation – a good balance for various low-power applications.
  • SPT-3: Thickest insulation – offers increased protection for slightly higher power applications compared to SPT-1 and SPT-2.

Additional Variations:

  • SPT-1W & SPT-2W: These variations have the same conductor size and insulation thickness as SPT-1 and SPT-2, respectively, but with a white outer jacket instead of the standard black or brown. This might be used for aesthetic purposes or to differentiate them from other cords.
  • SPT-2-R: This code signifies an SPT-2 cord with a designated ground (green or bare) conductor in addition to the two power conductors. This type is rarely used in residential applications.

Important Notes:

  • SPT cords are not rated for outdoor use and should never be exposed to moisture or sunlight.
  • They have a low voltage rating (typically 300 volts) and are not suitable for high-power applications.
  • Due to their limited capabilities, consult a qualified electrician before using SPT cords for extension cords exceeding recommended lengths or for applications with higher power requirements.
Type Specification Conductor Construction No./ mm Insulation thickness (mm) Overall Diameter (mm) Max conductor resistance at 20˚C (Ω/km)
No. Of core AWG Bare Tinned
SPT-1 2 18 41/0.160 0.76 2.8±0.2×5.6±0.2 22.4 23.6
3 18 41/0.160 0.76 2.8±0.2×8.0±0.2 22.4 23.6
SPT-2 2 8 41/0.160 1.14 3.5±0.2×7.0±0.2 22.4 23.6
16 65/0.160 1.14 3.8±0.2×7.4±0.2 14.1 14.9
3 18 41/0.160 1.14 3.5±0.2×9.0±0.2 22.4 23.6
16 65/0.160 1.14 3.8±0.2×10.0±0.2 14.1 14.9
3 18 41/0.160 1.14 3.5±0.2×10.1±0.2 22.4 23.6
16 65/0.160 1.14 3.8±0.2×11.1±0.2 14.1 14.9
SPT-3 2 18 41/0.160 1.52 4.4±0.2×8.7±0.2 22.4 23.6
16 65/0.160 1.52 4.7±0.2×9.5±0.2 14.1 14.9
14 41/0.160 2.03 6.0±0.2×12.0±0.2 8.88 9.34
12 65/0.160 2.41 7.5±0.2×14±0.2 5.58 5.88
3 18 41/0.160 1.52 4.4±0.2×10.8±0.2 22.4 23.6
16 65/0.160 1.52 4.7±0.2×12.0±0.2 14.1 14.9
14 41/0.254 2.03 6.0±0.2×14.5±0.2 8.88 9.34
12 65/0.254 2.41 7.5±0.2×16.0±0.2 5.58 5.88
10 104/0.254 2.79 8.8±0.2×18.2±0.2 3.51 3.70